Abstract
This paper presents a method to predict the direct- and quadrature-axes operational impedances and starting performance of permanent-magnet (PM) motors by a simple standstill response testing method using a small-capacity DC power supply unit. In this method, not only the starting performance but also the direct- and quadrature-axes synchronous machine constants (synchronous, transient, and subtransient reactances) and equivalent circuit constants are calculated. This proposed strategy, tentatively named the DC decay testing method, is carried out on a 3.7-kW 200-V 22. A 100-Hz four-pole interior PM motor with a damper winding. The results measured by on-load tests and those predicted by the proposed method on starting performance demonstrate the validity and usefulness of the proposed method.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.