Abstract

This paper presents a method to predict the direct- and quadrature-axes operational impedances and starting performance of permanent-magnet (PM) motors by a simple standstill response testing method using a small-capacity DC power supply unit. In this method, not only the starting performance but also the direct- and quadrature-axes synchronous machine constants (synchronous, transient, and subtransient reactances) and equivalent circuit constants are calculated. This proposed strategy, tentatively named the DC decay testing method, is carried out on a 3.7-kW 200-V 22. A 100-Hz four-pole interior PM motor with a damper winding. The results measured by on-load tests and those predicted by the proposed method on starting performance demonstrate the validity and usefulness of the proposed method.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.