Abstract

Wet flue gas desulfurization is widely used in power plants because of its high desulfurization efficiency. The reason why it is difficult to predict sulfur dioxide removal efficiency in flue gas is that it is related to many factors. In this paper, the SO2 was removed by absorbing with ammonia solution in a packed tower. Experimental studies have shown that the operating conditions affecting the removal of sulfur dioxide include pH, liquid-to-gas, the concentration of SO2 and inlet velocity. Based on the two-film theory, the mass transfer rate equation of SO2 in the ammonia desulphurization process was studied, and the prediction of SO2 removal efficiency based on certain assumptions was developed. In order to prove the responsibility of the model, significant factors such as pH, liquid-to-gas, the concentration of SO2, and inlet velocity were studied in a packed tower. The experimental results show that it is possible to improve desulphurization efficiency by increasing the liquid-to-gas ratio and pH value, lowering the concentration of SO2 and inlet velocity. Experimental results show that the experimental value is consistent with the predicted value.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call