Abstract

Measurements have been made on fluoropolymer seals of leakage rates, sealing force and compression set over a limited range of temperature and irradiation conditions to compare these techniques for their effectiveness in determining seal lifetimes. The results obtained indicate that the use of compression set tests in the routine assessment of seal performance is justified. Compression set measurements have been made on a polyurethane and a fluoropolymer over a range of temperature and radiation dose rates. The time-temperature superposition principle has been used to determine the thermal and dose rate shift factors a T , a R and activation energy E a for both materials. Determination of the functional dependence of a T , a R and E a on the dose rate enables realistic lifetime predictions to be made even when dose rate effects and temperature-radiation synergism are present.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.