Abstract

This paper aims to evaluate the influence of using additional middle-thickness rebar mesh (mid-mesh) on improving the punching shear behavior of interior slab-column connection. Sixteen two-way slabs were cast and tested including different flexural, compression, and mid-mesh reinforcement ratios at different levels of concrete strength. The performance of code-based expressions in predicting the punching shear capacity of reinforced concrete flat plates was also ascertained. The results indicated that using additional mid-mesh showed an increase in the punching shear capacity of slabs reached up to 17.7%. The results also indicated that the ACI 318-19 and CSA A23.1-19 codes underestimate the punching shear strength of tested slabs. Eurocode showed the closest predictions of the ultimate shear load compared to the other design codes investigated in this study. The authors also proposed an equation that can help the designers/engineers to accurately predict the punching shear capacity of intermediate slab–column connection with and/or without additional mid-mesh reinforcement.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.