Abstract

This paper presents different CPT methodologies for the prediction of the pile shaft resistance in tension on the example of three reference screw piles of the Jazowa test site in Poland. The shaft capacity was estimated based on the cone resistance, sleeve friction and CPT excess pore water pressure. Three piles with a diameter of 0.4 m and the length varied from 8 m to 14.6 m were subjected to static load tests in tension. Their results were used to determine the ultimate bearing capacity of the reference piles. The pile shaft resistance was estimated according to the AFNOR standard, Doan and Lehane 2018 centrifuge tests based method (Delft University of Technology approach), the Modified Unicone method, KTRI (Kajima Technical Research Institute) and LCPC (Laboratoire Central des Ponts et Chaussées) method. Then, the ultimate bearing capacity determined in static load tests was compared to the estimated values according to five different methods. The best estimation, fitting almost perfectly to static load test values, was obtained with the AFNOR method, whereas the other predictions significantly underestimated the ultimate bearing capacity.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.