Abstract
ABSTRACTEvaluation and measurement of the influence of changes in conditions and electrolyte composition during early stages of a growing metal electrodeposit are crucial to predict changes in developing morphology. A galvanodynamic polarisation technique was developed to reliably measure overpotentials for nickel electrodeposition from sulphate electrolyte. The validity of these polarisation parameters as indicators of the relationships between changes in the electrolyte and resulting deposit morphology was evaluated for electrolytes of varying composition. Findings indicate that nucleation and plating overpotentials measured by the described technique can be used as indicative tools for monitoring, evaluating and ultimately improving control of the electrodeposition of nickel from sulphate electrolytes. The results predict that nickel deposits of desirable quality and morphology are obtained when plating overpotentials are higher than 700 mV vs. Ag/AgCl and nucleation overpotential is less negative than plating overpotential.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.