Abstract

Inclusion bodies (IBs) were solubilized in a µ-scale system using shaking microtiter plates or a stirred tank reactor in a laboratory setting. Characteristic dimensionless numbers for mixing, the Phase number Ph and Reynolds number Re did not correlate with the kinetics and equilibrium of protein solubilization. The solubilization kinetics was independent of the mixing system, stirring or shaking rate, shaking diameter, and energy input. Good agreement was observed between the solubilization kinetics and yield on the µ-scale and laboratory setting. We show that the IB solubilization process is controlled predominantly by pore diffusion. Thus, for the process it is sufficient to keep the IBs homogeneously suspended, and additional power input will not improve the process. The high-throughput system developed on the µ-scale can predict solubilization in stirred reactors up to a factor of 500 and can therefore be used to determine optimal solubilization conditions on laboratory and industrial scale.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.