Abstract

ABSTRACTThis study focuses mainly on the prediction of saturated flow boiling heat transfer in microchannels. A wide range of experiments has been carried out with de-ionized water to obtain a comprehensive data set. Experiments of mass fluxes of 51–728.7 kg/m2s, wall heat fluxes of 36–221.7 kW/m2, vapor qualities of 0.01–0.69, liquid Reynolds number of 7.72–190, aspect ratios of 0.37–5.00 (with a constant hydraulic diameter of 100 µm) and hydraulic diameters of 100–250 µm (for constant aspect ratio = 1). A new correlation including the aspect ratio effect is proposed to predict the heat transfer coefficient for saturated flow boiling in microchannels. The proposed correlation shows very good predictions with an overall mean absolute error of 16.9% and 86.4%, 96.2% and 99.5% of the predicted data falling within ±30, ±40 and ±50% error bands, respectively.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.