Abstract

BackgroundOsteoporosis has increased and developed into a serious public health concern worldwide. Despite the high prevalence, osteoporosis is silent before major fragility fracture and the osteoporosis screening rate is low. Abdomen-pelvic CT (APCT) is one of the most widely conducted medical tests. Artificial intelligence and radiomics analysis have recently been spotlighted. This is the first study to evaluate the prediction performance of femoral osteoporosis using machine-learning analysis with radiomics features and APCT.Materials and methods500 patients (M: F = 70:430; mean age, 66.5 ± 11.8yrs; range, 50–96 years) underwent both dual-energy X-ray absorptiometry and APCT within 1 month. The volume of interest of the left proximal femur was extracted and 41 radiomics features were calculated using 3D volume of interest analysis. Top 10 importance radiomic features were selected by the intraclass correlation coefficient and random forest feature selection. Study cohort was randomly divided into 70% of the samples as the training cohort and the remaining 30% of the sample as the validation cohort. Prediction performance of machine-learning analysis was calculated using diagnostic test and comparison of area under the curve (AUC) of receiver operating characteristic curve analysis was performed between training and validation cohorts.ResultsThe osteoporosis prevalence of this study cohort was 20.8%. The prediction performance of the machine-learning analysis to diagnose osteoporosis in the training and validation cohorts were as follows; accuracy, 92.9% vs. 92.7%; sensitivity, 86.6% vs. 80.0%; specificity, 94.5% vs. 95.8%; positive predictive value, 78.4% vs. 82.8%; and negative predictive value, 96.7% vs. 95.0%. The AUC to predict osteoporosis in the training and validation cohorts were 95.9% [95% confidence interval (CI), 93.7%-98.1%] and 96.0% [95% CI, 93.2%-98.8%], respectively, without significant differences (P = 0.962).ConclusionPrediction performance of femoral osteoporosis using machine-learning analysis with radiomics features and APCT showed high validity with more than 93% accuracy, specificity, and negative predictive value.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.