Abstract

In this paper, the characteristics of a two-way ball valve orifice are researched. By means of modeling and analyzing of the trajectory of valve opening angle, a conclusion was drawn that there was trigonometric function relationship between the orifice area and opening angle of a ball valve. Based on this, the bench tests are conducted with the spraying system with 6 nozzles. It can be seen that there is a good agreement between prediction model established and experiment by the method of border points checking, the absolute error is in the range of 0~0.002mm2. With further research, there is a marked logarithmic relationship between the orifice area of a ball valve and flow of the sprayer, the correlation coefficient is 0.9952.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.