Abstract

Local heat transfer coefficients were experimentally measured for evaporation of R417A (R125/R134a/R600) flowing inside horizontal smooth and two internally grooved tubes with different geometrical parameters. The experimental results of R417A inside different test tubes were analyzed and compared with existing correlations; several microfin correlations failed to predict heat transfer coefficients of refrigerant mixtures and could not express the local variation of heat transfer coefficients during the evaporation. Based on the experimental data of R417A, an empirical correlation for microfin tubes was developed by introducing the enhancement factors into the modified Kattan model. The comparison of the calculations and the experimental results reveals that the microfin correlation suggested at the present study generally predicts experimental data with a deviation of ±30% for vapor qualities below 80% and also expresses the local variation of heat transfer coefficients for refrigerant mixtures evaporating inside microfin tubes.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.