Abstract

Reported studies on T-head Square-neck One-side Bolts (TSOBs) bolted I-beam to Hollow Section Square Column (HSSC) connections demonstrated the potential of TSOB applications in terms of mechanical properties, installation construction, and cost savings [11–14]. However, existing research was limited to the connection tests and lack a systematic and complete design approach. In this paper, the method for predicting the bending moment capacities and failure modes of the connections was proposed based on the existing test researches. Besides, the Finite Element Model (FEM) of the connections was established and validated by the reported test results. A sensitive analysis on the geometric parameters of the plastic hinge line pattern for calculating the bending moment capacity of the HSSC connecting face was carried out by the validated FEM. The proposed method was compared with the numerical simulation method in terms of the predicted results of the connection structural behavior. The results show that the prediction method proposed in this paper for the connection bending moment capacities and failure modes is accurate and reliable. Moreover, the mixed patterns of Type-H bolt holes and Type-V bolt holes are recommended for the TSOBC design because of the higher bending moment capacity than the unitary bolt hole patterns.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call