Abstract

Corrosion under insulation (CUI) is a progressive problem for piping systems in oil and gas industries especially in petrochemical and chemical plants due to its catastrophic disasters and consequently its automatic impact on the environment. To ensure CUI problem should not spark sudden surprise in plants, indeterminate factors that contribute to the deterioration of pipes subject to CUI should be recognized and taken care seriously. Operating temperature, type of environment, insulation type, pipe complexity and insulation condition of the pipes are the key factors that cause significant deterioration of pipes due to CUI. As per its varying nature, CUI is difficult to predict as it remains hidden beneath the insulation and gets growth in an ambiguous and abrupt manner. For such an uncertain and critical situation, fuzzy logic is a good choice to be deal with. Thus, in this study, CUI corrosion rate for insulated carbon steel piping systems has been predicted by fuzzy logic using API 581 data. Predicted CUI corrosion rates obtained by the developed fuzzy logic model are committing quite satisfactory results when comparing with API 581 published CUI corrosion rates. At the end of study, sensitivity analysis (SA) of CUI producing factors has also been performed. SA is showing the role of each CUI producing factor in terms of percentage, having participation for the cause of 1 mm/year CUI in pipes. The predicted CUI corrosion rates and SA will help inspection engineers for setting and delivering the risk-based inspection priority for insulated piping systems at their concerned plants.

Highlights

  • Corrosion under Insulation (CUI) is one of the main reasons of failure in insulated piping systems in oil and gas industries

  • In 2003, a study made by Exxon Mobile Chemical indicated that the main cause of leaks in the chemical and refining industries is CUI and 81% of piping leaks were found in pipes having diameters smaller than

  • 4.1 CUI corrosion rates obtained from developed fuzzy logic model

Read more

Summary

Introduction

Corrosion under Insulation (CUI) is one of the main reasons of failure in insulated piping systems in oil and gas industries. The less availability of CUI corrosion rate field data and indefinite behavior of CUI on piping systems have made CUI a very complex and complicated problem. This is the reason CUI corrosion rate cannot be predicted using conventional methods. A detailed literature review was conducted, which revealed that many researchers have used fuzzy logic for the prediction of different types of corrosion for attaining the same objective, i.e. to alleviate the maintenance system of the industry with reference to the problem of corrosion. Further details for concerned literature review can be seen in [9] by the same authors

CUI corrosion rate by API 581 for carbon steel pipes
CUI corrosion rate fuzzy logic model
Sensitivity analysis for CUI producing factors
CUI corrosion rates obtained from developed fuzzy logic model
Outcomes from sensitivity analysis
Conclusion
Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call