Abstract
A pump with a specific speed of 12000 was chosen to operate as a turbine (PAT) for a micro-hydro site having 5 m of head. Turbine performance of the pump was unavailable so it was simulated using CFD. The CFD model was first verified by comparison of simulated pump performance and manufacturer data. Simulated PAT performance covered a range of flow rates, from one to three times that of pump best efficiency point (BEP), for blade angles of 0 and ± 4°. The PAT BEP was located at a flow rate of 1.4 times that of pump BEP and a head of 1.6 times. For the specific site this corresponded to a shaft power of 32 k W and a flow rate of 770 1/s. The PAT was found to have an extended range of good efficiency, > 60%, for up to 3 times the pump BEP flow rate.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.