Abstract
To investigate the factors associated with and impact on the femtosecond-assisted (FS-assisted) limbal relaxing incision (LRI) combined with the steep-meridian tri-planar clear corneal incision (TCCI) to reduce astigmatism in patients undergoing Implantable Collamer Lens (ICL) surgery. Retrospective case series. The study reviewed patients with ICL surgery combined with FS-assisted LRIs paired with steep-meridian TCCIs. Correlation analysis examined the relationship between independent variables, including preoperative characteristics (intraocular pressure, corneal thickness, axial length, et al.), TCCI, and LRI surgical parameters. The predictors of surgically induced astigmatism (SIA) were determined using individual-level analysis and accounting for inter-eye correlation with the generalized estimating equation (GEE). The study enrolled 69 patients, with 114 eyes (55 right and 59 left). The mean spherical equivalent (SEQ) was - 10.29 ± 2.99D and - 9.99 ± 2.72D for the right and left eye, respectively, while the mean preoperative corneal astigmatism was - 1.54 ± 0.47D and - 1.54 ± 0.46D for the right and left eyes, respectively. After 12 months of follow-up, univariate analysis revealed significant correlations between SIA and intraocular pressure (IOP), astigmatism type, TCCI position (degree), peripheral corneal thickness (PCT), LRI arc incision diameter, post depth (%), and angle, respectively (P = 0.046, 0.016, 0.039, 0.040, 0.009, 0.000, 0.000). Multivariate analysis using GEE demonstrated that axial length (AL), astigmatism type, LRI arc diameter, and angle were independent predictors of SIA (P = 0.000, 0.005, 0.029, 0.000). The type of astigmatism and axial length were independent factors that affected SIA when modifying the LRI arc diameter and angle through FS-assisted steep-meridian TCCI paired with LRI in ICL surgery.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: Graefe's archive for clinical and experimental ophthalmology = Albrecht von Graefes Archiv fur klinische und experimentelle Ophthalmologie
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.