Abstract
Prior to performing a robot-assisted coronary artery bypass grafting procedure, a pre-operative computed tomography scan is used to assess patient candidacy and to identify the location of the target vessel. The surgeon then determines the optimal port locations to ensure proper reach to the target with the robotic instruments, while assuming that the heart does not undergo any significant changes between the pre- and intra-operative stages. However, the peri-operative workflow itself leads to changes in heart position and consequently the intra-operative target vessel location. As such, the pre-operative plan must be adequately updated to adjust the target vessel location to better suit the intraoperative condition. Here we propose a technique to predict the position of the peri-operative target vessel location with approximately 3.5 mm RMS accuracy. We believe this technique will potentially reduce the rate of conversion of robot-assisted procedures to traditional open-chest surgery due to poor planning.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.