Abstract

Abstract Background and aim High degree conduction disturbances is a burdensome complication of transcatheter aortic valve implantation (TAVI). There is limited data whether such disorders are permanent or reversible. Anatomic surrogates, such as membranous septum [MS, a distance marker from aortic annulus to His-bundle surge] and calcium distribution within aortic valve have been associated with pacemaker (PM) implantation. The aim of our study was to assess predictors of long-term pacemaker dependency following TAVI. Methods Single center prospectively included patients that underwent pacemaker implantation following TAVI (March 2017 to September 2020). Patients who were lost to follow up, with bicuspid aortic valve, previously implanted PM and non-available or low quality MSCT exam were excluded. On MSCT, MS length was measured on modified coronal view, the aortic-valvular complex (AVC) was characterized by leaflet sector and calcium distribution was assessed on a J-score threshold of 850-Hounsfield units. Pacemaker dependency was assessed by reducing ventricular pacing to 30 bpm and defined by subsequent complete AV dissociation in patients in sinus rhythm or an escape rhythm <50 bpm in atrial fibrillation, in addition of >90% pacing percentage since implantation. Results From the 352 patients with inclusion criteria, 67 underwent PM implantation (19%) and 55 included in the analysis (male 33.9%, median age=85) (Figure). Median time for pacemaker implantation was 3 days [interquartile range (IQR) 3–5 days], mostly due to complete auriculo-ventricular block (76.4%, N=42). PM dependency occurred in 14 out of 55 (25.5%) patients at mean follow up of 500±363 days. Patients with PM dependency tended to have deeper implantation depth, (6.2 mm vs 5.5 mm, p=0.096) and a significantly shorter MS (5.8 mm vs 6.8 mm, P-value = 0.031) (Table). Increasing MS length was independently associated with a lower risk of PM dependency [odds ratio (OR) 0.58 per mm; 95% CI: 0.35–0.98, p=0.04] regardless prosthesis choice. MS length under 5 mm had 97.6% specificity (95% CI: 87.1–99.9) and 85.7% positive predictive value for pacemaker dependency (AUC=76.7; 95% CI 63.3–87). Conclusion Our findings highlight the importance of MSCT-derived MS length to stratify the risk of long term need for pacemaker. Patients with short MS (<5mm) in addition to conduction abnormality following TAVI had a high likelihood of PM dependency on the long term and should be considered for prompt PM implantation. Funding Acknowledgement Type of funding sources: None.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call