Abstract
Equations describing quantitatively the relation between Fe 3+ dose and residual arsenic concentration, C e, at pH values ranging between 6 and 8 and various initial arsenic concentrations, C o, were established using a natural water spiked with As(V). These equations were used to calculate the specific arsenic removal, q, in μg As removed per mg Fe 3+ added. In turn, reliable equations relating q and C e in the range between 2 and 20 μg As/L were derived. The latter equations predicted Fe 3+ dose, necessary to achieve any selected C e, when the water's C o and pH were known, with a satisfactory degree of accuracy (relative standard deviation less than 15%). In addition, comparison of As(V) removal data from full scale water treatment plants to those predicted by the empirical equations presented in this work, corroborated the fact that these equations can serve as a reliable guide for the prediction of Fe 3+ dose necessary to remove As(V) from drinking water. The process of arsenic removal by using Fe 3+ as a coagulant was found to be exothermic in character and C e showed an increase by a factor of about 1.5 for each 10 °C increase in temperature.
Published Version
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.