Abstract

BackgroundThe estimation of arterial blood gas and lactate from central venous blood analysis and pulse oximetry (SpO2) readings has not yet been extensively validated. MethodsIn this multicentre, prospective study performed in 590 patients with acute circulatory failure, we measured blood gases and lactate in simultaneous central venous and arterial blood samples at 6 h intervals during the first 24 h after insertion of central venous and arterial catheters. The study population was randomly divided in a 2:1 ratio into model derivation and validation sets. We derived predictive models of arterial pH, carbon dioxide partial pressure, oxygen saturation, and lactate, using clinical characteristics, SpO2, and central venous blood gas values as predictors, and then tested their performance in the validation set. ResultsIn the validation set, the agreement intervals between predicted and actual values were −0.078/+0.084 units for arterial pH, −1.32/+1.36 kPa for arterial carbon dioxide partial pressure, −5.15/+4.47% for arterial oxygen saturation, and −1.07/+1.05 mmol litre−1 for arterial lactate (i.e. around two times our predefined clinically tolerable intervals for all variables). This led to ∼5% (or less) of extreme-to-extreme misclassifications, thus giving our predictive models only marginal agreement. Thresholds of predicted variables (as determined from the derivation set) showed high predictive values (consistently >94%), to exclude abnormal arterial values in the validation set. ConclusionsUsing clinical characteristics, SpO2, and central venous blood analysis, we predicted arterial blood gas and lactate values with marginal accuracy in patients with circulatory failure. Further studies are required to establish whether the developed models can be used with acceptable safety.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call