Abstract

The purpose of this retrospective study was to evaluate the predictability and accuracy of maxillary repositioning during bimaxillary surgery using a three-dimensional positioning technique. Twenty-six adult patients who underwent bimaxillary surgery requiring high superior maxillary impactions were divided into 2 groups. In group A, a three-dimensional positioning technique during maxillary repositioning was used along with an intermediate occlusal splint. In group B, only an intermediate occlusal splint with internal reference points was used. Both groups had measurements from predictive tracings compared to postoperative cephalograms to assess the accuracy of horizontal and vertical movements of the maxilla. Group A showed excellent correlation between the planned and actual maxillary positions in vertical and horizontal dimensions. In group B, the maxilla tended to move anteriorly than planned. Use of the three-dimensional positioning technique offered a predictive and accurate method for maxillary repositioning.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.