Abstract

In this work, the separations and preconcentrations of Zn(II) and Hg(II) ions on Bacillus lichenifoemis loaded onto Amberlite XAD-4 resin by solid-phase extraction has been performed. The biosorbent was characterized by using FT-IR, SEM, and EDX. pH, sample flow rate, eluent type and concentration, amount of B. licheniformis and XAD-4 resin, sample volume, and possible interfering ions effect were investigated in detailsas experimental variables in the SPE procedure. Limit of detection values for Zn(II) and Hg(II) were detected as 0.03 and 0.06ngmL-1, respectively. 0.2-15ngmL-1 linear range values were achieved for Zn(II) and Hg(II), respectively. Relative standard deviation values were found to be lowerthan 5%. For validation of the procedure, the certified standard reference materials (CWW-TM-D, EU-L-2, NCS ZC73O14, NCS ZC73350) were analyzed. The concentrations of Zn(II) and Hg(II) in water and food samples were measured by ICP-OES. Consequently, it can be inferred that the immobilized B. licheniformis microcolumn has ideal selectivity for Zn(II) and Hg(II) biosorption.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.