Abstract

Introduction111In-BzDTPA-pertuzumab is a novel imaging probe for detecting changes in HER2 expression in breast cancer (BC) caused by treatment with trastuzumab (Herceptin). Our aim was to evaluate the pharmacokinetics, normal tissue biodistribution, radiation dosimetry and acute toxicity of 111In-BzDTPA-pertuzumab in non-tumor bearing mice in order to obtain regulatory approval to advance this agent to a first-in-humans Phase I/II clinical trial. MethodsBiodistribution and pharmacokinetic studies were performed in non-tumor bearing Balb/c mice injected i.v. with 111In-BzDTPA-pertuzumab (2.5MBq; 2μg). The cumulative number of disintegrations per source organ derived from the biodistribution data was used to predict the radiation absorbed doses in humans using OLINDA/EXM software. Acute toxicity was studied at two weeks post-injection of 111In-BzDTPA-pertuzumab (1.0MBq, 20μg) with comparison to control mice injected with unlabeled BzDTPA-pertuzumab (20μg) or Sodium Chloride Injection USP. The dose of 111In-BzDTPA-pertuzumab corresponded to 23-times the human radioactivity dose and 10-times the protein dose on a MBq/kg and mg/kg basis, respectively. Toxicity was assessed by monitoring body mass, complete blood cell count (CBC), hematocrit (Hct), hemoglobin (Hb), serum creatinine (SCr) and alanine aminotransferease (ALT) and by histopathological examination of tissues at necropsy. Results111In-BzDTPA-pertuzumab exhibited a biphasic elimination from the blood with a distribution half-life (t1/2α) of 3.8h and an elimination half-life (t1/2β) of 228.2h. The radiopharmaceutical was distributed mainly in the blood, heart, lungs, liver, kidneys and spleen. The projected whole-body radiation absorbed dose in humans was 0.05mSv/MBq corresponding to a total of 16.8mSv for three separate administrations of 111In-BzDTPA-pertuzumab (111MBq) planned for the Phase I/II trial. There were slight changes in Hb and SCr levels associated with administration of multiples of the human dose in healthy Balb/c mice but no histopathological abnormalities were noted in any tissues. There were no significant differences in body mass between mice injected with 111In-BzDTPA-pertuzumab or control mice. ConclusionPreclinical studies predicted that 111In-BzDTPA-pertuzumab is safe to administer to humans at a dose of 111MBq (5mg). The radiopharmaceutical exhibited preclinical pharmacokinetic, biodistribution and radiation dosimetry properties suitable for advancement to a first-in-humans clinical trial. Advances in knowledge and implications for patient careThe results of these studies supported the regulatory approval by Health Canada of 111In-BzDTPA-pertuzumab for a Phase I/II clinical trial of for imaging the response of patients with metastatic BC to treatment with trastuzumab combined with chemotherapy (PETRA trial; ClinicalTrials.gov identifier: NCT01805908).

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.