Abstract

A precision measurement of the Casimir force using metallic gold surfaces is reported. The force is measured between a large gold-coated sphere and flat plate using an atomic force microscope. The use of gold surfaces removes some theoretical uncertainties in the interpretation of the measurement. The forces are also measured at smaller surface separations. The complete dielectric spectrum of the metal is used in the comparison of theory to the experiment. The average statistical precision remains at the same 1% of the forces measured at the closest separation. These results should lead to the development of stronger constraints on hypothetical forces.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.