Abstract

The laser ablation threshold’s dependence on the pulse duration is a powerful tool that can be used to aid in understanding the mechanism of laser ablation. To determine the expected value of the ablation threshold accurately, it is essential to increase the number of data points available for analysis. In this study, we developed an automatic pulse-duration-tunable laser processing system with an in situ monitor that can collect more than 10,000 data points in a few hours. The laser system was operated at a wavelength of 1050 nm with a repetition rate of 1 MHz, and the pulse duration was tuned from 0.53 to 31 ps. Multi-shot ( $${10}^5$$ pulses) ablation thresholds for silicon were measured with an average error of less than 1%. We found that there were two ablation thresholds, at a fluence of $$0.22\ \hbox {J}/\hbox {cm}^2$$ with a pulse duration below 4 ps and at an intensity of $$24\ \hbox {GW}/\hbox {cm}^2$$ of intensity with a pulse duration above 13 ps.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.