Abstract

The application of inductively coupled plasma mass spectrometry (ICP-MS) is discussed in the case study of Precambrian mafic and ultramafic rocks of eastern Fennoscandian shield and their mineral components. Determination of bulk probe sample composition is reported to be possible using both the chemical digestion of samples and in situ laser ablation (LA-ICP-MS). The accuracy of the analyses was monitored by analyzing the USGS standard BHVO-2, Russian standard SGD-1A, and in-house reference materials. The composition and measurement results of in-house reference materials С-1412, KN1 and KK1 are presented. The effect of ablation modes on the accuracy and reproducibility of LA-ICP-MS elemental concentration analysis was explored for standards, minerals and rocks. The sensitivity of the method is indicated to depend not only on the physicochemical properties of the samples (melting temperature, volatility), but also on the ablation mode and analysis procedure.

Highlights

  • В статье обсуждается методика масс спектрометрии с индуктивно связанной плаз мой (ICP MS) на примере анализа результатов изучения докембрийских мафитов и ультрамафитов восточной части Фенноскандинавского щита и слагающих их ми нералов

  • The accuracy of the analyses was monitored by analyzing the USGS standard BHVO 2, Russian standard SGD 1A, and in house reference materials

  • The effect of ablation modes on the accuracy and reproducibility of LA inductively coupled plasma mass spectrometry (ICP MS) elemental concentration analysis was explored for standards, minerals and rocks

Read more

Summary

Introduction

В статье обсуждается методика масс спектрометрии с индуктивно связанной плаз мой (ICP MS) на примере анализа результатов изучения докембрийских мафитов и ультрамафитов восточной части Фенноскандинавского щита и слагающих их ми нералов. 1. Результаты тестовых измерений химическо го состава стандартных образцов СГД 1А (серия из 14 измерений) и BHVO 2 (10 измерений) методом ICP MS на квадрупольном масс спектрометре X Series 2 (Thermo Fisher Scientific) в аналитической лаборатории ИГ КарНЦ РАН в 2013–2015 годах.

Results
Conclusion
Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.