Abstract
A detailed analysis for accuracy and sensitivity of fiber-optic sensor based on white-light interferometric technique with wavelength scanning is presented. Analytical equations for optimal optical path difference were obtained, which allow to reach the minimum measurement uncertainty. The results of the analysis can be applied for optimization of any sensor based on low coherence spectrum domain technique, though our experimental validation of analysis has been carried out with the temperature sensor based on the Sagnac interferometer having a twisted high-birefringent fiber as a sensing element.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.