Abstract
The procedure is described for increasing the precision of the method of testing the asymmetrical aberrations with an inverting confocal Fabry-Perot interferometer. The appropriate choice of the registration plane of the interference pattern and subtraction of respective wavefronts (obtained with a changed sign of asymmetrical wave aberrations) make possible testing of aberrations with a sensitivity of the order of lambda/50. The experimental results are discussed. The use of the method proposed to control the centering quality of the optical systems or elements is described.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.