Abstract
In this paper, we report a T and F intercomparison experiment between the National Physical Laboratory (NPL), New Delhi, India and Physikalisch-Technische Bundesanstalt (PTB), Federal Republic of Germany, carried out from May 16 to June 29, 1979. The participating earth stations were New Delhi, India and Raisting, FRG. The NPL clock was placed at New Delhi Earth Station and the Raisting Clock was calibrated with PTB/Primary standard via LORAN-C and travelling clocks. The random uncertainty of time comparisons, represented by two sample Allan Variance σ(30 seconds), was less than 10 nanoseconds. The relative frequency difference between the NPL and Raisting Clocks, SNPL, RAIS, as measured over the 44 days period was found to be-15.7 × 10-13. The relative frequency difference between PTB Primary Standard and Raisting Clock, SPTB, RAIS during this period, was measured to be–22.8 × 10-13. The relative frequency difference between NPL clock and PTB Primary Standard, SNPL, PTB, thus, is—7.1 × 10-13.The clock ra...
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.