Abstract

A precise frequency synchronization detection method is proposed based on the group quantization steeping law. Based on the different-frequency group quantization phase processing, high-precision frequency synchronization can be achieved by measuring phase comparison result quantization. If any repeated phase differences in the quantized phase comparison results are used as the starting and stopping signal of the counter gate, the time interval between identical phase differences is a group period as gate time. By measuring and analyzing the quantized phase comparison results, the ±1−word counting error is overcome in the traditional frequency synchronization detection method, and the system response time is significantly shortened. The experimental results show that the proposed frequency synchronization detection method is advanced and scientific. The measurement resolution is notably stable and the frequency stability better than the E-12/s level can be obtained. The method is superior to the traditional frequency synchronization detection method in many aspects, such as system reliability and stability, detection speed, development cost, power consumption and volume.

Highlights

  • The frequency difference between two signals is obtained by measuring the phase difference, and the high-precision frequency synchronization is realized

  • According to the measurement principle based on phase quantization processing, the key to improving the measurement accuracy is the acquisition of phase comparison results and phase difference measurement in phase comparison results

  • The phase comparison results are obtained by detecting the phases of two processed signals

Read more

Summary

Introduction

The frequency difference between two signals is obtained by measuring the phase difference, and the high-precision frequency synchronization is realized. In recent years, regarding the traditional high-resolution phase-processing problem, to either optimize algorithm or improve the production process, the principle and processing method of phase measurement have not changed, but the measurement accuracy has been improved. K. Klepacki realized the phase difference measurement with 7.5 ps resolution by combining high-frequency pulse filling and fine delay [1], David Vyhlidal et al improved this method, made the resolution of the phase difference measurement reach 0.17 ps order of magnitude, and obtained the time interval measurement precision with 2.1 ps [2]. The improved work of David Vyhlidal broadened the range of phase difference measurement, improved the linearity of measurement, and reduced the development cost of the measurement system.

Methods
Results
Discussion
Conclusion