Abstract

The precise frequency comparison system is of great importance in many applications. A frequency comparison method based on the phase coincidence demarcation (PCD) is proposed, and a frequency comparison system based on the proposed method is realized. The proposed method solves the uncertainty problem of the phase coincidence detection circuit by using two analog-to-digital converter (ADC) chips to demarcate the phase coincidence points. The test results indicate that the precision of the realized frequency comparison system is 10−16 (Allan deviation) at 1000 s.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.