Abstract

A theoretical model of electrohydrodynamic prebreakdown phenomena in slightly ionized (weakly conductive) media is proposed. The electric high voltage conduction of weakly conductive liquids and slightly ionized gases in intense electric fields using this model is considered. The formula for the calculations of volt–ampere characteristics under high voltage spherical capacitor field is analytically obtained. The experimental corona discharge volt–ampere characteristics of air are presented. It was found that the size of the ionization region in the case of corona discharge in air increases monotonically with increasing discharge voltage.