Abstract

IntroductionThe aim of this paper is to present results of first two years of preanalytical external quality assessment (EQA) in Croatia.Materials and methodsThis paper summarizes results from 6 rounds of preanalytical EQA during 2014-2016 in 161-175 Croatian laboratories (number ranged between cycles). EQA was designed as an online survey of the compliance with National recommendations for phlebotomy (NRP). Forty-seven questions in 5 categories are analyzed (materials and equipment, patient identification, patient preparation, sampling and storage). Additionally, preanalytical cases are presented. Overall performance scores (Question score (Qscore) for compliance with NRP and Case score (Cscore) for preanalytical cases) are calculated for each question/case as a proportion of laboratories with satisfactory procedure (x 100). Qscores and Cscores ≥ 70 were classified as acceptable (maximal score = 100).ResultsIn investigation of compliance with NRP, acceptable Qscores were obtained for 34/47 questions. The lowest scores were observed for the availability of sterile disposable tourniquets (Qscore = 15) and safe-sharp needles (Qscore = 34), obtaining patients address as an identifier (Qscore = 21), using glycolysis inhibitor tubes for glucose concentration measurement (Qscore = 21) and verification of manufacturers declarations on temperature and time of storage (Qscore = 31). There was no statistically significant difference in overall Qscore according to different categories of phlebotomy procedures (P = 0.284). The results of preanalytical cases showed acceptable Cscore values for all cases (89-96).ConclusionFirst two years of preanalytical EQA showed good compliance with the NRP and excellent expertise in resolving complex preanalytical issues. Major critical spots are lack of availability of safe-sharp needles, disposable tourniquets and glucose inhibitor tubes.

Highlights

  • The aim of this paper is to present results of first two years of preanalytical external quality assessment (EQA) in Croatia

  • In investigation of compliance with National recommendations for phlebotomy (NRP), acceptable Question score (Qscore) were obtained for 34/47 questions

  • The lowest scores were observed for the availability of sterile disposable tourniquets (Qscore = 15) and safe-sharp needles (Qscore = 34), obtaining patients address as an identifier (Qscore = 21), using glycolysis inhibitor tubes for glucose concentration measurement (Qscore = 21) and verification of manufacturers declarations on temperature and time of storage (Qscore = 31)

Read more

Summary

Introduction

The aim of this paper is to present results of first two years of preanalytical external quality assessment (EQA) in Croatia. External quality assessment (EQA) of the analytical phase of laboratory work has, for some time, been established as an essential tool for quality assurance. Many different providers available at the market ensure that laboratories can choose the schemes that best meet their needs regarding the cost, sample quality, time of delivery or quality of reports. ©Copyright by Croatian Society of Medical Biochemistry and Laboratory Medicine.

Objectives
Methods
Results
Conclusion
Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.