Abstract

To evaluate the ability to assess the coronary arteries using pre-procedural computed tomography (CT; high-pitch mode) in patients referred for transcatheter aortic valve implantation (TAVI). CT and invasive coronary angiography (ICA) were performed pre-TAVI in 100 patients (46 women; 79±5.9 years). CT was performed in prospectively ECG-triggered high-pitch mode after intravenous administration of 70 ml iodinated contrast medium. Image quality was assessed using a four-point scale (graded 0-3). Significant coronary artery stenosis (≥50% diameter) was graded as either present or absent by one observer and in one-third of patients by two observers independently. ICA was the standard of reference. Results were reported per segment and per patient. Twenty-two percent of patients had known coronary artery disease (CAD). In two cases, a coronary anomaly was detected. Diagnostic image quality (grade 1-3) was achieved in 30.3% of segments. Sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) were 75%, 80.5%, 16%, and 98.5%, respectively. Significant coronary stenosis could be ruled out completely in all segments in three patients. The interrater agreement per patient was excellent (kappa=1). Relevant coronary findings can frequently be observed in high-pitch TAVI-planning CT. Despite the limitations of the technique and in patients referred to pre-TAVI evaluation (rapid heart rate, coronary calcifications, etc.), a valid evaluation of coronary arteries is possible in a considerable proportion of segments with a high NPV; however, few studies were completely free of motion artefacts to dependably exclude CAD using this technique in this challenging group of patients.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call