Abstract

Hypoxaemia during anaesthetic induction in obstetrics is hazardous for mother and baby, but the onset of desaturation can be delayed by pre-oxygenation. This study investigated pre-oxygenation during pregnancy using computer simulation. The Nottingham Physiology Simulator was configured to replicate normal pregnant physiology. Three pregnant and three non-pregnant subjects were created, representing population variation according to published physiological values. They underwent pre-oxygenation by tidal and vital capacity breathing of 100% oxygen. Pre-oxygenation during tidal breathing proceeded more rapidly in pregnancy, the median [range] time to achieve 95% of the maximum change in P(E)O2 being 1 min 37 s [1:23-1:52] in pregnant subjects, compared to 2 min 51 s [2:28-3:15] in non-pregnant subjects. Vital capacity pre-oxygenation required seven breaths [5-10] in pregnant subjects, compared to six breaths [4-9] in non-pregnant subjects, to achieve the same P(E)O2 as after 95% complete tidal pre-oxygenation. We recommend 2 min of tidal breathing for pre-oxygenation in pregnancy.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.