Abstract

Electromechanical switching devices such as relays may be surprisingly forgiving to occasional, but temporary, electrical stress beyond specification. Consequently delayed openings due to welded contacts on the order of milliseconds usually have been unnoticed and hence have not been reason for concern. However, as electrical systems of vehicles are getting smarter and more and more diagnostic routines are being implemented, even such short delay times may be translated as errors. Pre-conditioning contact surfaces has been explored as a measure to increase the welding resistance and eliminate contact opening delays. The 20-A-class relay investigated has been optimized to break occasional current peaks up to 80 ADC.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.