Abstract

IntroductionMany approaches for automated treatment planning (autoplanning) have been proposed and investigated. Autoplanning can enhance plan quality compared to ‘manual’ trial-and-error planning, and decrease routine planning workload. A few approaches have been implemented in commercial treatment planning systems (TPSs). We performed a pre-clinical validation of a new system (‘NovelATP’) that is based on fully-automated multi-criterial optimization (MCO). The aim of NovelATP is to automatically generate for each patient a single high-quality, Pareto-optimal plan without manual Pareto navigation. Material and methodsValidation was performed by generating VMAT/IMRT plans for conventional treatment of prostate cancer (101 pts), prostate SBRT (20 pts), bilateral head-and-neck cancer (50 pts) and rectal cancer treated at an MR-Linac (23 pts). NovelATP autoplans were compared to plans that were generated with our in-house autoplanning system. In many previous validation studies, the latter system consistently showed enhanced plan quality when compared to manual planning. ResultsDosimetrical differences between NovelATP and benchmark plans were on average small and presumably not clinically relevant, pointing at high NovelATP dosimetric plan quality. MUs were 11–19% higher with NovelATP. NovelATP delivery times were up to 12% longer. Overall, there was a slight disadvantage for NovelATP regarding gamma analyses. Calculation times for NovelATP plans were between 29 and 151 min with no overall differences with the benchmark plans. ConclusionThe new autoplanning system was able to produce high-quality plans for four highly different planning protocols/treatment sites with a total of 194 patients investigated.

Highlights

  • Many approaches for automated treatment planning have been proposed and investigated

  • We performed a pre-clinical validation of a new system (‘NovelATP’) that is based on fully-automated multi-criterial optimization (MCO)

  • Material and methods: Validation was performed by generating VMAT/IMRT plans for conventional treatment of prostate cancer (101 pts), prostate SBRT (20 pts), bilateral head-and-neck cancer (50 pts) and rectal cancer treated at an MR-Linac (23 pts)

Read more

Summary

Introduction

Many approaches for automated treatment planning (autoplanning) have been proposed and investigated. The aim of NovelATP is to automatically generate for each patient a single high-quality, Pareto-optimal plan without manual Pareto navigation. In many previous validation studies, the latter system consistently showed enhanced plan quality when compared to manual planning. Results: Dosimetrical differences between NovelATP and benchmark plans were on average small and presumably not clinically relevant, pointing at high NovelATP dosimetric plan quality. Calculation times for NovelATP plans were between 29 and 151 min with no overall differences with the benchmark plans. Conclusion: The new autoplanning system was able to produce high-quality plans for four highly different planning protocols/treatment sites with a total of 194 patients investigated.

Objectives
Methods
Results
Conclusion
Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call