Abstract

To improve the quality of diagnosing pulmonary tuberculosis (TB), WHO recommends the use of rapid molecular testing as an alternative to conventional microscopic methods. Loop-mediated isothermal amplification assay (LAMP test) is a practical and cost-effective nucleic amplification technique. We evaluated the pragmatic accuracy of an in-house LAMP assay for the diagnosis of TB in a remote health care setting where an advanced rapid molecular test is not available. A prospective diagnostic accuracy study was conducted. Patients with clinical symptoms suggestive of TB were consecutively enrolled from April to August 2016. Sputum samples were collected from each patient and were sent for microscopic examination (both acid-fast stain and fluorescence stain), in-house LAMP test, and TB culture. One hundred and seven patients with TB symptoms were used in the final analysis. This included 50 (46.7%) culture-positive TB patients and 57 (53.3%) culture-negative patients. The overall sensitivity of the in-house LAMP based on culture positivity was 88.8% (95/107) with a 95%CI of 81.2-94.1. The sensitivity was 90.9% (40/44) with a 95%CI of 78.3-97.5 for smear-positive, culture-positive patients, and was 16.7% (1/6) with a 95%CI of 0.4-64.1 for smear-negative, culture-positive patients. The overall sensitivity of the in-house LAMP test compared to smear microscopy methods were not significantly different (p = 0.375). The specificity of the in-house LAMP based on non-TB patients (smear-negative, culture-negative) was 94.7% (54/57) with a 95%CI of 85.4-98.9. The diagnostic accuracy of the in-house LAMP test in a community hospital was comparable to other previous reports in terms of specificity. The sensitivity of the in-house assay could be improved with better sputum processing and DNA extraction method.

Highlights

  • Tuberculosis (TB), an airborne communicable disease, has long been considered a significant threat to global public health

  • Sputum samples were collected from each patient and were sent for microscopic examination, in-house Loop-mediated isothermal amplification (LAMP) test, and TB culture

  • The overall sensitivity of the in-house LAMP based on culture positivity was 88.8% (95/107) with a 95%CI of 81.2–94.1

Read more

Summary

Introduction

Tuberculosis (TB), an airborne communicable disease, has long been considered a significant threat to global public health. The incidence and prevalence of TB vary greatly across the globe, 87% of total cases resided within 30 countries with a high TB burden. Novel diagnostic methods with enough simplicity and cost-effectiveness are necessary to improve the accurate identification of TB patients in those resource-limited settings [3,4]. To improve the quality of diagnosing pulmonary tuberculosis (TB), WHO recommends the use of rapid molecular testing as an alternative to conventional microscopic methods. Loopmediated isothermal amplification assay (LAMP test) is a practical and cost-effective nucleic amplification technique. We evaluated the pragmatic accuracy of an in-house LAMP assay for the diagnosis of TB in a remote health care setting where an advanced rapid molecular test is not available

Objectives
Methods
Results
Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.