Abstract

BackgroundWhile intercenter variation (ICV) in anti-epileptic drug (AED) use in neonates with seizures has been previously reported, variation in AED practices across regional NICUs has not been specifically and systematically evaluated. This is important as these centers typically have multidisciplinary neonatal neurocritical care teams and protocolized approaches to treating conditions such as hypoxic ischemic encephalopathy (HIE), a population at high risk for neonatal seizures. To identify opportunities for quality improvement (QI), we evaluated ICV in AED utilization for neonates with HIE treated with therapeutic hypothermia (TH) across regional NICUs in the US.MethodsChildren’s Hospital Neonatal Database and Pediatric Health Information Systems data were linked for 1658 neonates ≥36 weeks’ gestation, > 1800 g birthweight, with HIE treated with TH, from 20 NICUs, between 2010 and 2016. ICV in AED use was evaluated using a mixed-effect regression model. Rates of AED exposure, duration, prescription at discharge and standardized AED costs per patient were calculated as different measures of utilization.ResultsNinety-five percent (range: 83–100%) of patients with electrographic seizures, and 26% (0–81%) without electrographic seizures, received AEDs. Phenobarbital was most frequently used (97.6%), followed by levetiracetam (16.9%), phenytoin/fosphenytoin (15.6%) and others (2.4%; oxcarbazepine, topiramate and valproate). There was significant ICV in all measures of AED utilization. Median cost of AEDs per patient was $89.90 (IQR $24.52,$258.58).ConclusionsAmongst Children’s Hospitals, there is marked ICV in AED utilization for neonatal HIE. Variation was particularly notable for HIE patients without electrographic seizures, indicating that this population may be an appropriate target for QI processes to harmonize neuromonitoring and AED practices across centers.

Highlights

  • While intercenter variation (ICV) in anti-epileptic drug (AED) use in neonates with seizures has been previously reported, variation in AED practices across regional NICUs has not been and systematically evaluated

  • Background seizures occur in 26–65% of neonates with hypoxic-ischemic encephalopathy (HIE), it is well known that anti-epileptic drug (AED) management is variable among centers [1,2,3,4]

  • Study population Of the 120,601 infants included in the Children’s Hospital Neonatal Database (CHND) at the time of analysis, we identified 2903 neonates with hypoxic ischemic encephalopathy (HIE) treated with therapeutic hypothermia (TH)

Read more

Summary

Introduction

While intercenter variation (ICV) in anti-epileptic drug (AED) use in neonates with seizures has been previously reported, variation in AED practices across regional NICUs has not been and systematically evaluated. This is important as these centers typically have multidisciplinary neonatal neurocritical care teams and protocolized approaches to treating conditions such as hypoxic ischemic encephalopathy (HIE), a population at high risk for neonatal seizures. Seizures occur in 26–65% of neonates with hypoxic-ischemic encephalopathy (HIE), it is well known that anti-epileptic drug (AED) management is variable among centers [1,2,3,4].

Objectives
Methods
Results
Discussion
Conclusion

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.