Abstract

Interior tomography problem can be solved using the so-called differentiated backprojection-projection onto convex sets (DBP-POCS) method, which requires a priori knowledge within a small area interior to the region of interest (ROI) to be imaged. In theory, the small area wherein the a priori knowledge is required can be in any shape, but most of the existing implementations carry out the Hilbert filtering either horizontally or vertically, leading to a vertical or horizontal strip that may be across a large area in the object. In this work, we implement a practical DBP-POCS method with radial Hilbert filtering and thus the small area with the a priori knowledge can be roughly round (e.g., a sinus or ventricles among other anatomic cavities in human or animal body). We also conduct an experimental evaluation to verify the performance of this practical implementation. We specifically re-derive the reconstruction formula in the DBP-POCS fashion with radial Hilbert filtering to assure that only a small round area with the a priori knowledge be needed (namely radial DBP-POCS method henceforth). The performance of the practical DBP-POCS method with radial Hilbert filtering and a priori knowledge in a small round area is evaluated with projection data of the standard and modified Shepp-Logan phantoms simulated by computer, followed by a verification using real projection data acquired by a computed tomography (CT) scanner. The preliminary performance study shows that, if a priori knowledge in a small round area is available, the radial DBP-POCS method can solve the interior tomography problem in a more practical way at high accuracy. In comparison to the implementations of DBP-POCS method demanding the a priori knowledge in horizontal or vertical strip, the radial DBP-POCS method requires the a priori knowledge within a small round area only. Such a relaxed requirement on the availability of a priori knowledge can be readily met in practice, because a variety of small round areas (e.g., air-filled sinuses or fluid-filled ventricles among other anatomic cavities) exist in human or animal body. Therefore, the radial DBP-POCS method with a priori knowledge in a small round area is more feasible in clinical and preclinical practice.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.