Abstract

Abstract The linear polarization technique in principle is a convenient and rapid way for determining corrosion rates. In practice, one finds that it is often applied under conditions alien to the assumptions on the basis of which it was derived. This paper will present a series of comparative observations between linear polarization, resistance probe, and weight loss measurements in different systems. The systems studied were: (1) Hydrochloric acid containing acetylenic inhibitors, (2) a two phase system containing hydrocarbon and water saturated with H2S, and (3) tap water containing various inhibitors. An equation will be derived showing the effect of ohmic resistance due to corrosion product buildup. The effect of polarization on the properties of a corrosion product layer will be discussed qualitatively.