Abstract
Abstract The increasing electrical design and physical complexity of semiconductor devices, especially in the analog and mixed signal (AMS) applications, directly influences the development and evolution of fault isolation techniques. One of these techniques is Dynamic Laser Stimulation (DLS) which is widely used in the industry for effective identification of subtle failure mechanisms and soft defects especially for AC signal-related failures [1, 2]. However, for analysis of some complex AMS IC failure modes, the tool’s standard setup may not always be compatible with the biasing requirements of the device. For example, the setup would typically require expensive and intricate test systems (i.e. Automatic test equipment (ATE), SCAN tester, etc.) to be interfaced with the DLS tool for the analysis to be feasible and successful [3, 4]. This paper presents simple and practical techniques to implement DLS without the need for an expensive test support system. These techniques were applied in three different FA cases involving AMS ICs with complex and temperature-dependent failure modes. The results of subsequent analysis indicated success in isolating the exact defect sites.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.