Abstract
This paper describes the design methodology for auxiliary resonant snubber inverters including /spl Delta/- and Y-configured auxiliary resonant snubber inverters. The design emphases are resonant circuit components including inductor, capacitor, end switch, DC link capacitor, and control technique. Design optimization can be aimed at high efficiency, high frequency, low dV/dt, or compact size. An example of designing a three-phase 100 kVA unit is described step by step. Hardware implementation and experimental results are shown for verification.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.