Abstract

The HTSC transformer with a separate winding for excitation of the mutual magnetic flux is considered; the windings of the transformer are performed of first- or second-generation HTSC wires. The article presents the design and the electrical circuit of the transformer, the equations of electromagnetic balance, and the total resistance of the primary and secondary power windings and the separate excitation winding. The transfer of the electromagnetic field energy is considered in a single-phase HTSC transformer with the separate excitation winding using the Poynting vector. The temporal change in the reactive and active components of the Poynting vector and the decrease in the leakage energy flux of the separate excitation winding are shown, which causes an increase in the critical current density of the HTSC power windings, a decrease in the energy losses in the latter, and an increase the in the specific power of the HTSC transformer.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.