Abstract

Power transport to the Poloidal Divertor Experiment graphite scoop limiter was measured during both ohmic- and neutral-beam-heated discharges by observing its front face temperatures using an infrared camera. Measurements were made as a function of a plasma density, current, position, fueling mode, and heating power for both co- and counter-neutral beam injection. The measured thermal load on the scoop limiter was 25 to 50%. of the total plasma heating power. The measured peak front face midplane temperature was 1500/sup 0/C, corresponding to a peak surface power density of 3 kW/cm/sup 2/. This power density implies an effective parallel power flow of 54 kW/cm/sup 2/ in agreement with the radial power distribution extrapolated from television Thomson scattering and calorimetry measurements.