Abstract

The aim of this paper is to perform the relative study of power quality problems in a grid tied solar PV system, with and without vibration connected to a parallel pumping system at 1.0 bar set pressure by using two control techniques such as VVC+ & V/f. In case of vibrations, the effect of motor vibration problems on the dynamic performance and electrical power quality of water pumping system will be observed. Vibrations are introduced in the pumping system by loosening the base plate of the pumps. During motor vibrations, the instantaneous flicker values become high which leads to variation in the supply voltage and torque imbalance. The effect of power quality parameters in a solar feeder during normal conditions and vibrating conditions are analysed. In normal condition, the THD increases and the flicker is high only during transient period due to sudden voltage variations. A comparison has been made to observe the appropriate control method for pumping system with and without vibrations in a solar PV-grid connected system.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.