Abstract

This paper presents power quality improvement of PMSG (Permanent Magnet Synchronous Generator) based DG (Diesel Generator) set feeding a 3-phase 3-wire load using STATCOM (Distribution Static Compensator). A 3-leg VSC (Voltage Source Converter) with a capacitor on the DC link is used as STATCOM. The reference source currents for the system are estimated using a Adaline based control algorithm. A PWM (Pulse Width Modulation) current controller is using for generation of gating pulses of IGBTs of three leg VSC of the STATCOM. The STATCOM is able to provide voltage control, harmonics elimination, power factor improvement, load balancing and load compensation. The performance of the system is experimentally test on various types of loads under steady state and dynamic conditions. A 3-phase induction motor with variable frequency drive is used as a prototype of diesel engine with speed regulation. So, the DG set is run at constant speed so that frequency of supply remains constant irrespective of loading condition.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.