Abstract

Power electronic converters are used for integrating renewable energy sources such as wind and photovoltaic into the grid. This integration gives rise to many challenges in power systems, especially regarding power quality. Indeed, integrated systems generate a non-linear current full of harmonics, which degrades power quality. Active power filters are usually used to compensate for these harmonics at the point of common coupling. In the control of active power filters, harmonics need to be extracted from the non-linear current. In this paper, the matrix pencil method―a model-based technique for estimating parameters of exponentially damped or undamped sinusoids in noise―is proposed to extract the reference signal in shunt active power filter applications. The performance of the proposed matrix pencil method is studied for current harmonic compensation and power factor correction under different modulation schemes and two DC links: an external DC voltage source and a capacitor. Using a capacitor for the DC link requires not only including a proportional-plus-integral controller to maintain a constant capacitor voltage, but also accounting for the loss current in the formulation of the matrix pencil method. Compared with the instantaneous reactive power theory and synchronous reference frame, results obtained from simulated data using MATLAB/Simulink under different loading conditions show that the proposed method corrects the power factor and affords a lower source current total harmonic distortion and fast response.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call