Abstract

This letter focuses on the power module (PM) capacitor voltage balancing of a $\pm 350$ -kV/1000-MW modular multilevel converter (MMC). For this MMC, the current flowing through the IGBTs will exceed the nominal current of the adopted commercial high-voltage (3.3 kV or higher) IGBT products, i.e., 1500 A. As for the PM voltage balancing of this MMC, the switching frequency must be kept low to reduce the losses and the accurate calculation of the PM switching frequency is of great importance to the design of the cooling system. This letter presented a low-switching frequency PM balancing method by introducing the balancing adjusting number (BAN). The PM switching frequency calculation method is also presented with different BANs. Computer simulation and the real-time control hardware in the loop test results based on RT-LAB show the effectiveness of the proposed PM balancing method and the accuracy of the switching frequency calculation method under the rated power.