Abstract

High-resistance connection (HRC) is a common electrical fault in the electric machine drive system. This paper presents the power loss analysis of five phase permanent magnet synchronous motor (PMSM) drive system with HRC fault. In this paper, the model of five phase PMSM is given under healthy and HRC fault conditions. The power loss, mainly focusing on the copper loss under HRC fault condition is studied, which provide the convenience for further research on how to reduce the power loss under HRC fault condition. The control strategy of five phase PMSM is introduced. The simulation is carried out to quantitatively study the copper loss of the PMSM drive system under healthy and fault conditions.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.