Abstract
This study presents a technique for power frequency AC voltage measurement. The proposed technique utilises a capacitor having a low capacitance in addition to a double wound Rogowski coil. This technique depends on capacitor current measurement using the double wound Rogowski coil. The voltage across the capacitor that connected in parallel with the system at which AC voltage is intended to be measured is reconstructed. The proposed technique is experimentally evaluated by designing the measurement system and using a digital signal processing board for the reconstruction processes. Moreover, the experimental results based on Rogowski coil measurements are compared with those obtained from reference techniques. Finally, the obtained results validate the efficacy of the proposed technique in power frequency AC voltage measurement.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.